<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Archívy 17 - 20,5 [kg] - MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</title>
	<atom:link href="https://marvelpit.sk/en/hmotnost/17-205-kg-en/feed/" rel="self" type="application/rss+xml" />
	<link>https://marvelpit.sk/en/hmotnost/17-205-kg-en/</link>
	<description>Central european business company Marvel - Electric actuators, Valves</description>
	<lastBuildDate>Fri, 26 Sep 2025 13:14:27 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://marvelpit.sk/wp-content/uploads/2018/08/cropped-marvel_logo_4_1-32x32.png</url>
	<title>Archívy 17 - 20,5 [kg] - MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</title>
	<link>https://marvelpit.sk/en/hmotnost/17-205-kg-en/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Electric part-turn actuator SPR 2.3 PA</title>
		<link>https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-3-pa/</link>
					<comments>https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-3-pa/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Thu, 25 Jan 2024 14:19:44 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/?post_type=product&#038;p=11699</guid>

					<description><![CDATA[<p>SPR 2.3 PA &#8211; electric part-turn actuator &#160; Standard equipment and functions of the actuators with DMS3 Supply voltage 230 V AC Terminal board connection Protection of the motor against overheating Switching off in limit positions from the position or torque Adjustable switching off-torque from 50% to 100% Torque blocking in limit positions Torque blocking [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-3-pa/">Electric part-turn actuator SPR 2.3 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>SPR 2.3 PA &#8211; electric part-turn actuator</h2>
<p>&nbsp;</p>
<h2>Standard equipment and functions of the actuators with DMS3</h2>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>Protection of the motor against overheating</li>
<li>Switching off in limit positions from the position or torque</li>
<li>Adjustable switching off-torque from 50% to 100%</li>
<li>Torque blocking in limit positions</li>
<li>Torque blocking during the start</li>
<li>2 freely programmable relays R1, R2 (18 functions)</li>
<li>Relay READY</li>
<li>Control by unified signal 0/4 &#8211; 20 mA, 4 &#8211; 12 mA, 12 &#8211; 20 mA,<br />
or 0/2 &#8211; 10 V (not for DMS3 in 2P version)</li>
<li>Control voltage for remote control 24 V DC</li>
<li>Impulse control (inching duty)</li>
<li>Timing mode / regime of operation</li>
<li>Safety function ESD (failure reaction)</li>
<li>Electronic position transmitter 4-20 mA passive (not for DMS3 in 2P version)</li>
<li>Auxiliary voltage output 24 V DC, max. 40 mA for supply of the control inputs</li>
<li>Output for failure messages</li>
<li>Space heater operated by control unit</li>
<li>LED position indicator</li>
<li>Communication interface RS 232</li>
<li>Programme for parameters setting by PC</li>
<li>Mechanical stop ends</li>
<li>Mechanical connection &#8211; flange ISO 5211</li>
<li>Manual control</li>
</ul>
<h2>Additional equipment of actuator with DMS3</h2>
<ul>
<li>Local control for actuators with DMS3 system</li>
<li>Additional relays RE3, RE4, RE5</li>
<li>Additional relay module RE1, RE2, RE3, RE4, RE5, READY</li>
<li>Version with control board PROFIBUS DP V0/V1</li>
<li>Version with control board MODBUS RTU</li>
</ul>
<p>&nbsp;</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-3-pa/">Electric part-turn actuator SPR 2.3 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-3-pa/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Explosion-proof electric linear actuator ULR 1 PA-Ex</title>
		<link>https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-ulr-1-pa-ex/</link>
					<comments>https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-ulr-1-pa-ex/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 23 May 2016 10:05:47 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/produkty/electric-linear-actuator-ulr-1pa-ex/</guid>

					<description><![CDATA[<p>ULR 1 PA-Ex &#8211; explosion-proof electric linear actuator &#160; Standard equipment and functions DMS3 Supply voltage 230 V AC Terminal board connection Protection of the motor against overheating Switching off in limit positions from the position or torque Adjustable switching-off torque  from 60% to 100% Torque blocking in limit positions Torque blocking during the start [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-ulr-1-pa-ex/">Explosion-proof electric linear actuator ULR 1 PA-Ex</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4></h4>
<h4>ULR 1 PA-Ex &#8211; explosion-proof electric linear actuator</h4>
<p>&nbsp;</p>
<h3>Standard equipment and functions DMS3</h3>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>Protection of the motor against overheating</li>
<li>Switching off in limit positions from the position or torque</li>
<li>Adjustable switching-off torque  from 60% to 100%</li>
<li>Torque blocking in limit positions</li>
<li>Torque blocking during the start</li>
<li>2 freely programmable relays R1, R2 (18 functions)</li>
<li>Relay READY</li>
<li>Control by unified signal 0/4 &#8211; 20 mA, 4 &#8211; 12 mA, 12 &#8211; 20 mA, or 0/2 &#8211; 10 V (not for DMS3 in 2P version)</li>
<li>Control voltage for remote control 24 V DC</li>
<li>Impulse control</li>
<li>Timing mode / regime of operation</li>
<li>Safety function ESD (failure reaction)</li>
<li>Electronic position transmitter 4-20 mA passive (not for DMS3 in 2P version)</li>
<li>Auxiliary voltage output 24 V DC, 40 mA for supply of the control inputs</li>
<li>Output for failure messages</li>
<li>Space heater operated by control unit</li>
<li>LED position indicator</li>
<li>Communication interface RS 232</li>
<li>Programme for parameters setting by PC</li>
<li>Mechanical stop ends</li>
<li>Mechanical connection &#8211; flange ISO 5211</li>
<li>Manual control</li>
</ul>
<h3>Additional equipment</h3>
<ul>
<li>Local control for actuators with DMS3 system</li>
<li>Additional relays RE3, RE4, RE5</li>
<li>Additional relay module RE1, RE2, RE3, RE4, RE5, READY</li>
<li>Version with control board PROFIBUS DP V0/V1</li>
<li>Version with control board MODBUS RTU</li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-ulr-1-pa-ex/">Explosion-proof electric linear actuator ULR 1 PA-Ex</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-ulr-1-pa-ex/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
