<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Archívy 10 - 100 [mm] - MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</title>
	<atom:link href="https://marvelpit.sk/en/pracovny-zdvih/10-100-mm/feed/" rel="self" type="application/rss+xml" />
	<link>https://marvelpit.sk/en/pracovny-zdvih/10-100-mm/</link>
	<description>Central european business company Marvel - Electric actuators, Valves</description>
	<lastBuildDate>Mon, 06 Oct 2025 13:59:13 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://marvelpit.sk/wp-content/uploads/2018/08/cropped-marvel_logo_4_1-32x32.png</url>
	<title>Archívy 10 - 100 [mm] - MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</title>
	<link>https://marvelpit.sk/en/pracovny-zdvih/10-100-mm/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Electric linear actuator ULR 2 PA</title>
		<link>https://marvelpit.sk/en/product/electric-linear-actuator-ulr-2-pa/</link>
		
		<dc:creator><![CDATA[tomas.lescisin@marvelpit.sk]]></dc:creator>
		<pubDate>Wed, 24 Sep 2025 14:46:22 +0000</pubDate>
				<guid isPermaLink="false">https://marvelpit.sk/?post_type=product&#038;p=13296</guid>

					<description><![CDATA[<p>ULR 2 PA &#8211; electric linear actuator &#160; Standard equipment and functions with DMS3 control unit Supply voltage 230 V AC Terminal board connection Protection of the electromotor against overheating Switching off in limit positions from position and from thrust Adjustable switching-off thrust from 50% to 100% Thrust blocking in limit positions Thrust blocking during the [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-ulr-2-pa/">Electric linear actuator ULR 2 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4></h4>
<h4>ULR 2 PA &#8211; electric linear actuator</h4>
<p>&nbsp;</p>
<h3>Standard equipment and functions with DMS3 control unit</h3>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>Protection of the electromotor against overheating</li>
<li>Switching off in limit positions from position and from thrust</li>
<li>Adjustable switching-off thrust from 50% to 100%</li>
<li>Thrust blocking in limit positions</li>
<li>Thrust blocking during the start</li>
<li>2 freely programmable relays R1, R2 (Not valid for Profibus and Modbus)</li>
<li>Relay READY (Not valid for Profibus and Modbus)</li>
<li>Control by unified signal 0/4 &#8211; 20 mA, 4 &#8211; 12 mA, 12 &#8211; 20 mA, or 0/2 &#8211; 10 V (Not valid for Profibus and Modbus)</li>
<li>Control by permanent voltage (+24 V DC) &#8211; OPEN, CLOSE</li>
<li>Impulse control (inching duty) (+24 V DC) &#8211; OPEN, STOP, CLOSE</li>
<li>Timing mode / regime of operation</li>
<li>Safety function ESD (failure reaction)</li>
<li>Electronic position transmitter 4 to 20 mA passive (not for DMS3 in 2P version) (Not valid for Profibus and Modbus)</li>
<li>Auxiliary voltage output 24 V AC, max. 40 mA for supply of the control inputs</li>
<li>Output of failure messages</li>
<li>Space heater operated by control unit</li>
<li>Communication interface RS 232</li>
<li>Programme for parameterization setting a PC</li>
<li>Mechanical connection &#8211; pillars</li>
<li>Manual control</li>
<li>Enclosure protection IP 66</li>
</ul>
<h3>Additional equipment</h3>
<ul>
<li>Supply voltage 220 V, 3&#215;380 V, 3&#215;400 V, 120 V/60 Hz, 110 V/60 Hz</li>
<li>Local control for actuators with DMS 3 system</li>
<li>Reversing unit for 3-phase supply voltage</li>
<li>Additional relays RE3, RE4, RE5</li>
<li>Additional relay module RE1, RE2, RE3, RE4, RE5, READY</li>
<li>Version with control board PROFIBUS DP V0/V1</li>
<li>Version with control board MODBUS RTU</li>
<li>Communication cable DB-9F/RJ45</li>
<li>Mechanical connection according to ISO 5210 &#8211; flange size F07</li>
<li>Mechanical connection according to ISO 5210 &#8211; flange size F10</li>
<li>Enclosure protection IP 68</li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-ulr-2-pa/">Electric linear actuator ULR 2 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electric linear actuator MTP</title>
		<link>https://marvelpit.sk/en/product/electric-linear-actuator-mtp/</link>
					<comments>https://marvelpit.sk/en/product/electric-linear-actuator-mtp/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 23 May 2016 12:03:08 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/produkty/mtp-servomotor-primocary-tahlovy-ip-67-2/</guid>

					<description><![CDATA[<p>MTP &#8211; electric linear actuator &#160; Usage Electric linear actuator MTP actuators are used for remote two-position or three-position control of the valves by a reverse rectilinear motion. The MODACT® MTP CONTROL actuators are fitted with an electronic position controller. In association with the valve exhibiting a suitable control characteristic, they form a position servo-loop. [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-mtp/">Electric linear actuator MTP</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>MTP &#8211; electric linear actuator</h2>
<p>&nbsp;</p>
<h2>Usage</h2>
<p><strong>Electric linear actuator MTP</strong> actuators are used for remote two-position or three-position control of the valves by a reverse rectilinear motion. <strong>The MODACT<sup>®</sup> MTP CONTROL</strong> actuators are fitted with an electronic position controller.</p>
<p>In association with the valve exhibiting a suitable control characteristic, they form a position servo-loop. The output pull-rod of these actuators is automatically brought into a position corresponding to the input signal value of the controller. The actuators can be used even for other devices for which they are in respect of their characteristics and parameters suitable. In some special cases, the contemplated use of the actuators should be consulted with the manufacturer.</p>
<h2>Documents for download</h2>
<ul>
<li><a href="https://marvelpit.sk/wp-content/uploads/2016/10/soubor_en_209.pdf" target="_blank" rel="noopener noreferrer">Catalog</a></li>
<li><a href="https://marvelpit.sk/wp-content/uploads/2016/10/soubor_en_210.pdf" target="_blank" rel="noopener noreferrer">Installation instructions</a></li>
<li><a href="https://marvelpit.sk/wp-content/uploads/2016/10/soubor_en_211.pdf" target="_blank" rel="noopener noreferrer">Addition to installation instructions</a></li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-mtp/">Electric linear actuator MTP</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-linear-actuator-mtp/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Explosion-proof electric linear actuator MTR 3 PA-Ex</title>
		<link>https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-mtr-3-pa-ex/</link>
					<comments>https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-mtr-3-pa-ex/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 23 May 2016 10:20:57 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/produkty/electric-linear-actuator-mtr-3pa-ex/</guid>

					<description><![CDATA[<p>MTR 3 PA-Ex &#8211; explosion-proof electric linear actuator &#160; Standard equipment and functions with DMS3 control unit Supply voltage 3&#215;400 V AC Terminal board connection Protection of the electromotor against overheating Switching off in limit positions from position and from thrust Adjustable switching-off thrust from 50% to 100% Thrust blocking in limit positions Thrust blocking during [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-mtr-3-pa-ex/">Explosion-proof electric linear actuator MTR 3 PA-Ex</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4></h4>
<h4>MTR 3 PA-Ex &#8211; explosion-proof electric linear actuator</h4>
<p>&nbsp;</p>
<h3>Standard equipment and functions with DMS3 control unit</h3>
<ul>
<li>Supply voltage 3&#215;400 V AC</li>
<li>Terminal board connection</li>
<li>Protection of the electromotor against overheating</li>
<li>Switching off in limit positions from position and from thrust</li>
<li>Adjustable switching-off thrust from 50% to 100%</li>
<li>Thrust blocking in limit positions</li>
<li>Thrust blocking during the start</li>
<li>7 freely programmable relays R1, R2, RE1 &#8230; RE5 (Not valid for Profibus and Modbus)</li>
<li>2 relay READY (Not valid for Profibus and Modbus)</li>
<li>Control by unified signal 0/4 &#8211; 20 mA, 4 &#8211; 12 mA, 12 &#8211; 20 mA, or 0/2 &#8211; 10 V (Not valid for Profibus and Modbus)</li>
<li>Control by permanent voltage (+24 V DC) &#8211; OPEN, CLOSE</li>
<li>Impulse control (inching duty) (+24 V DC) &#8211; OPEN, STOP, CLOSE</li>
<li>Timing mode / regime of operation</li>
<li>Safety function ESD (failure reaction)</li>
<li>Electronic position transmitter 4 to 20 mA passive (not for DMS3 in 2P version) (Not valid for Profibus and Modbus)</li>
<li>Auxiliary voltage output 24 V AC, max. 40 mA for supply of the control inputs</li>
<li>Output of failure messages</li>
<li>Space heater operated by control unit</li>
<li>Communication interface RS 232</li>
<li>Programme for parameterization setting by PC</li>
<li>Mechanical connection &#8211; pillars</li>
<li>Manual control</li>
<li>Enclosure protection IP 66</li>
</ul>
<h3>Additional equipment</h3>
<ul>
<li>Supply voltage:
<ul>
<li>3&#215;380 V, 230 V, 220 V / 50 Hz</li>
</ul>
</li>
<li>​Local control for actuators with DMS 3 system</li>
<li>Version with control board PROFIBUS DP V0/V1</li>
<li>Version with control board MODBUS RTU</li>
<li>Communication cable DB-9F/RJ45</li>
<li>Mechanical connection &#8211; flange</li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-mtr-3-pa-ex/">Explosion-proof electric linear actuator MTR 3 PA-Ex</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-mtr-3-pa-ex/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electric linear actuator MT 3-A</title>
		<link>https://marvelpit.sk/en/product/electric-linear-actuator-mt-3-a/</link>
					<comments>https://marvelpit.sk/en/product/electric-linear-actuator-mt-3-a/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 23 May 2016 10:20:27 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/produkty/electric-linear-actuator-mt-3-a/</guid>

					<description><![CDATA[<p>MT 3-A &#8211; electric linear actuator &#160; Standard equipment Supply voltage 230 V AC, 3&#215;400 V AC Terminal board connection 2 thrust switches 2 position switches 2 additional position switches Space heater with thermal switch Mechanical connection &#8211; flange and 4 pillars Mechanical position indicator Thrust switches blocking in limit positions Manual control Protection code [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-mt-3-a/">Electric linear actuator MT 3-A</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>MT 3-A &#8211; electric linear actuator</h2>
<p>&nbsp;</p>
<h2>Standard equipment</h2>
<ul>
<li>Supply voltage 230 V AC, 3&#215;400 V AC</li>
<li>Terminal board connection</li>
<li>2 thrust switches</li>
<li>2 position switches</li>
<li>2 additional position switches</li>
<li>Space heater with thermal switch</li>
<li>Mechanical connection &#8211; flange and 4 pillars</li>
<li>Mechanical position indicator</li>
<li>Thrust switches blocking in limit positions</li>
<li>Manual control</li>
<li>Protection code IP 55</li>
</ul>
<h2>Additional equipment</h2>
<ul>
<li>Supply voltage 220 V AC, 3&#215;380 V AC</li>
<li>Reverse contactors</li>
<li>Transmitter:<br />
&#8211; potentiometer: 1&#215;100 Ω, 1&#215;2000 Ω, 2&#215;100 Ω, 2&#215;2000 Ω<br />
&#8211; electronic position transmitter 0/4 &#8211; 20 mA, (passive/active)<br />
&#8211; CPT (capacitive) 4 &#8211; 20 mA, (passive/active)</li>
<li>Protection code IP 67</li>
</ul>
<h2>Documents for download</h2>
<ul>
<li><a href="https://marvelpit.sk/wp-content/uploads/2016/10/Gen_cond-Atom_sk-en.pdf" target="_blank" rel="noopener noreferrer">General conditions</a></li>
<li><a href="https://marvelpit.sk/wp-content/uploads/2016/10/MT_3-A_sk-en.pdf" target="_blank" rel="noopener noreferrer">Technical data sheet</a></li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-mt-3-a/">Electric linear actuator MT 3-A</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-linear-actuator-mt-3-a/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electric linear actuator MTR 3 PA</title>
		<link>https://marvelpit.sk/en/product/electric-linear-actuator-mtr-3-pa/</link>
					<comments>https://marvelpit.sk/en/product/electric-linear-actuator-mtr-3-pa/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 23 May 2016 10:12:50 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/produkty/electric-linear-actuator-mtr-3pa/</guid>

					<description><![CDATA[<p>MTR 3 PA &#8211; electric linear actuator &#160; Standard equipment and functions of the actuators with DMS3 Supply voltage 3&#215;400 V AC Terminal board connection Protection of the motor against overheating Switching off in limit positions from the position or thrust Adjustable switching-off thrust from 50% to 100% Torque (thrust) blocking in limit positions Torque [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-mtr-3-pa/">Electric linear actuator MTR 3 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4></h4>
<h4>MTR 3 PA &#8211; electric linear actuator</h4>
<p>&nbsp;</p>
<h3>Standard equipment and functions of the actuators with DMS3</h3>
<ul>
<li>Supply voltage 3&#215;400 V AC</li>
<li>Terminal board connection</li>
<li>Protection of the motor against overheating</li>
<li>Switching off in limit positions from the position or thrust</li>
<li>Adjustable switching-off thrust from 50% to 100%</li>
<li>Torque (thrust) blocking in limit positions</li>
<li>Torque (thrust) blocking during the start</li>
<li>7 freely programmable relays R1, R2, RE1, &#8230; RE5</li>
<li>Relay READY</li>
<li>Control by unified signal 0/4 &#8211; 20 mA, 4 &#8211; 12 mA, 12 &#8211; 20 mA, or 0/2 &#8211; 10 V (not for DMS3 in 2P version)</li>
<li>Control voltage for remote control 24 V DC (Open-Stop-Close)</li>
<li>Impulse control (inching duty)</li>
<li>Timing mode / regime of operation</li>
<li>Safety function ESD (failure reaction)</li>
<li>Electronic position transmitter 4-20 mA passive (not for DMS3 in 2P version)</li>
<li>Auxiliary voltage output 24 V DC, max. 40 mA for supply of the control inputs</li>
<li>Output for failure messages</li>
<li>Space heater operated by control unit</li>
<li>LED position indicator</li>
<li>Communication interface RS 232</li>
<li>Programme for parameters setting by PC</li>
<li>Mechanical connection &#8211; pillar</li>
<li>Manual control</li>
</ul>
<h3>Additional equipment of actuator with DMS3</h3>
<ul>
<li>Local control for actuators with DMS3 system</li>
<li>Version with control board PROFIBUS DP V0/V1</li>
<li>Version with control board Modbus RTU</li>
<li>Protection enclosure IP 67</li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-mtr-3-pa/">Electric linear actuator MTR 3 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-linear-actuator-mtr-3-pa/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electric linear actuator STR 2 PA</title>
		<link>https://marvelpit.sk/en/product/electric-linear-actuator-str-2-pa/</link>
					<comments>https://marvelpit.sk/en/product/electric-linear-actuator-str-2-pa/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 23 May 2016 10:10:34 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/produkty/electric-linear-actuator-str-2pa/</guid>

					<description><![CDATA[<p>STR 2 PA &#8211; electric linear actuator &#160; Standard equipment and functions of the actuators with DMS3 Supply voltage 230 V AC Terminal board connection Protection of the motor against overheating Switching off in limit positions from the position or thrust Adjustable switching-off thrust from 50% to 100% Torque (thrust) blocking in limit positions Torque [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-str-2-pa/">Electric linear actuator STR 2 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4></h4>
<h4>STR 2 PA &#8211; electric linear actuator</h4>
<p>&nbsp;</p>
<h3>Standard equipment and functions of the actuators with DMS3</h3>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>Protection of the motor against overheating</li>
<li>Switching off in limit positions from the position or thrust</li>
<li>Adjustable switching-off thrust from 50% to 100%</li>
<li>Torque (thrust) blocking in limit positions</li>
<li>Torque (thrust) blocking during the start</li>
<li>2 freely programmable relays RE1, RE2</li>
<li>Relay READY</li>
<li>Control by unified  signal 0/4 &#8211; 20 mA, 4 &#8211; 12 mA, 12 &#8211; 20 mA, or 0/2 &#8211; 10 V (not for DMS3 in 2P version)</li>
<li>Control voltage for remote control 24 V DC (Open-Stop-Close)</li>
<li>Impulse control (inching duty)</li>
<li>Timing mode / regime of operation</li>
<li>Safety function ESD (failure reaction)</li>
<li>Electronic position transmitter 4-20 mA passive  (not for DMS3 in 2P version)</li>
<li>Auxiliary voltage output 24 V DC, max. 40 mA for supply of the control inputs</li>
<li>Output for failure messages</li>
<li>Space heater operated by control unit</li>
<li>LED position indicator</li>
<li>Communication interface RS 232</li>
<li>Programme for parameters setting by PC</li>
<li>Mechanical position indicator</li>
<li>Mechanical connection &#8211; pillar</li>
<li>Manual control</li>
</ul>
<h3>Additional equipment of actuator with DMS3</h3>
<ul>
<li>Supply voltage 3&#215;400, 3&#215;380, 240, 220, 120, 24 V AC</li>
<li>Additional relays R3, R4, R5</li>
<li>Local control</li>
<li>Version with stand, lever and pull-rod</li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-str-2-pa/">Electric linear actuator STR 2 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-linear-actuator-str-2-pa/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electric linear actuator MT 3</title>
		<link>https://marvelpit.sk/en/product/electric-linear-actuator-mt-3/</link>
					<comments>https://marvelpit.sk/en/product/electric-linear-actuator-mt-3/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 23 May 2016 09:59:05 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/produkty/electric-linear-actuator-mt-3/</guid>

					<description><![CDATA[<p>MT 3 &#8211; electric linear actuator &#160; Standard equipment Supply voltage 3&#215;400 V AC Terminal board connection Protection of the motor against overheating 2 thrust switches 2 position switches 2 additional position switches Space heater with thermal switch Mechanical connection &#8211; pillar Mechanical position indicator Thrust switches blocking in limit positions Manual control Protection code [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-mt-3/">Electric linear actuator MT 3</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4></h4>
<h4>MT 3 &#8211; electric linear actuator</h4>
<p>&nbsp;</p>
<h3>Standard equipment</h3>
<ul>
<li>Supply voltage 3&#215;400 V AC</li>
<li>Terminal board connection</li>
<li>Protection of the motor against overheating</li>
<li>2 thrust switches</li>
<li>2 position switches</li>
<li>2 additional position switches</li>
<li>Space heater with thermal switch</li>
<li>Mechanical connection &#8211; pillar</li>
<li>Mechanical position indicator</li>
<li>Thrust switches blocking in limit positions</li>
<li>Manual control</li>
<li>Protection code IP 55</li>
</ul>
<h3>Additional equipment</h3>
<ul>
<li>Supply voltage 3&#215;380 V AC</li>
<li>Connector connection</li>
<li>Reverse contactors</li>
<li>Tandem switches</li>
<li>Transmitter:<br />
&#8211; potentiometer: 1&#215;100 Ω, 1&#215;2000 Ω, 2&#215;100 Ω, 2&#215;2000 Ω<br />
&#8211; electronic position transmitter 0/4 &#8211; 20 mA, (passive/active)</li>
<li>Mechanical connection &#8211; flange</li>
<li>Local control &#8211; after consulting with producer</li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-mt-3/">Electric linear actuator MT 3</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-linear-actuator-mt-3/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Explosion-proof electric linear actuator MT 3-Ex</title>
		<link>https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-mt-3-ex/</link>
					<comments>https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-mt-3-ex/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 23 May 2016 09:49:59 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/produkty/explosion-proof-electric-linear-actuator-mt-3-ex/</guid>

					<description><![CDATA[<p>MT 3-Ex &#8211; explosion-proof electric linear actuator &#160; Standard equipment Supply voltage 230 V AC, 3&#215;400 V AC Terminal board connection 2 thrust switches 2 position switches 2 additional position switches Space heater Mechanical connection &#8211; pillars Manual control Protection code IP 66 Additional equipment Supply voltage 3&#215;380 V AC Transmitter: &#8211; potentiometer: 1&#215;100 Ω, [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-mt-3-ex/">Explosion-proof electric linear actuator MT 3-Ex</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4></h4>
<h4>MT 3-Ex &#8211; explosion-proof electric linear actuator</h4>
<p>&nbsp;</p>
<h3>Standard equipment</h3>
<ul>
<li>Supply voltage 230 V AC, 3&#215;400 V AC</li>
<li>Terminal board connection</li>
<li>2 thrust switches</li>
<li>2 position switches</li>
<li>2 additional position switches</li>
<li>Space heater</li>
<li>Mechanical connection &#8211; pillars</li>
<li>Manual control</li>
<li>Protection code IP 66</li>
</ul>
<h3>Additional equipment</h3>
<ul>
<li>Supply voltage 3&#215;380 V AC</li>
<li>Transmitter:<br />
&#8211; potentiometer: 1&#215;100 Ω, 2&#215;100 Ω</li>
<li>Mechanical connection &#8211; flange</li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-mt-3-ex/">Explosion-proof electric linear actuator MT 3-Ex</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-mt-3-ex/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
