<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Electric actuators - MARVEL P.I.&amp;T. | MARVEL-BMT</title>
	<atom:link href="https://marvelpit.sk/en/product-category/electric-actuators/feed/" rel="self" type="application/rss+xml" />
	<link>https://marvelpit.sk/en/product-category/electric-actuators/</link>
	<description>Central european business company Marvel - Electric actuators, Valves</description>
	<lastBuildDate>Mon, 06 Oct 2025 13:57:28 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://marvelpit.sk/wp-content/uploads/2018/08/cropped-marvel_logo_4_1-32x32.png</url>
	<title>Electric actuators - MARVEL P.I.&amp;T. | MARVEL-BMT</title>
	<link>https://marvelpit.sk/en/product-category/electric-actuators/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Electric linear actuator ULR 2 PA</title>
		<link>https://marvelpit.sk/en/product/electric-linear-actuator-ulr-2-pa/</link>
		
		<dc:creator><![CDATA[tomas.lescisin@marvelpit.sk]]></dc:creator>
		<pubDate>Wed, 24 Sep 2025 14:46:22 +0000</pubDate>
				<guid isPermaLink="false">https://marvelpit.sk/?post_type=product&#038;p=13296</guid>

					<description><![CDATA[<p>ULR 2 PA &#8211; electric linear actuator &#160; Standard equipment and functions with DMS3 control unit Supply voltage 230 V AC Terminal board connection Protection of the electromotor against overheating Switching off in limit positions from position and from thrust Adjustable switching-off thrust from 50% to 100% Thrust blocking in limit positions Thrust blocking during the [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-ulr-2-pa/">Electric linear actuator ULR 2 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4></h4>
<h4>ULR 2 PA &#8211; electric linear actuator</h4>
<p>&nbsp;</p>
<h3>Standard equipment and functions with DMS3 control unit</h3>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>Protection of the electromotor against overheating</li>
<li>Switching off in limit positions from position and from thrust</li>
<li>Adjustable switching-off thrust from 50% to 100%</li>
<li>Thrust blocking in limit positions</li>
<li>Thrust blocking during the start</li>
<li>2 freely programmable relays R1, R2 (Not valid for Profibus and Modbus)</li>
<li>Relay READY (Not valid for Profibus and Modbus)</li>
<li>Control by unified signal 0/4 &#8211; 20 mA, 4 &#8211; 12 mA, 12 &#8211; 20 mA, or 0/2 &#8211; 10 V (Not valid for Profibus and Modbus)</li>
<li>Control by permanent voltage (+24 V DC) &#8211; OPEN, CLOSE</li>
<li>Impulse control (inching duty) (+24 V DC) &#8211; OPEN, STOP, CLOSE</li>
<li>Timing mode / regime of operation</li>
<li>Safety function ESD (failure reaction)</li>
<li>Electronic position transmitter 4 to 20 mA passive (not for DMS3 in 2P version) (Not valid for Profibus and Modbus)</li>
<li>Auxiliary voltage output 24 V AC, max. 40 mA for supply of the control inputs</li>
<li>Output of failure messages</li>
<li>Space heater operated by control unit</li>
<li>Communication interface RS 232</li>
<li>Programme for parameterization setting a PC</li>
<li>Mechanical connection &#8211; pillars</li>
<li>Manual control</li>
<li>Enclosure protection IP 66</li>
</ul>
<h3>Additional equipment</h3>
<ul>
<li>Supply voltage 220 V, 3&#215;380 V, 3&#215;400 V, 120 V/60 Hz, 110 V/60 Hz</li>
<li>Local control for actuators with DMS 3 system</li>
<li>Reversing unit for 3-phase supply voltage</li>
<li>Additional relays RE3, RE4, RE5</li>
<li>Additional relay module RE1, RE2, RE3, RE4, RE5, READY</li>
<li>Version with control board PROFIBUS DP V0/V1</li>
<li>Version with control board MODBUS RTU</li>
<li>Communication cable DB-9F/RJ45</li>
<li>Mechanical connection according to ISO 5210 &#8211; flange size F07</li>
<li>Mechanical connection according to ISO 5210 &#8211; flange size F10</li>
<li>Enclosure protection IP 68</li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-ulr-2-pa/">Electric linear actuator ULR 2 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electric linear actuator ULR 1 PA</title>
		<link>https://marvelpit.sk/en/product/electric-linear-actuator-ulr-1-pa/</link>
		
		<dc:creator><![CDATA[tomas.lescisin@marvelpit.sk]]></dc:creator>
		<pubDate>Tue, 23 Sep 2025 10:30:55 +0000</pubDate>
				<guid isPermaLink="false">https://marvelpit.sk/?post_type=product&#038;p=13283</guid>

					<description><![CDATA[<p>ULR 1 PA &#8211; electric linear actuator &#160; Standard equipment and functions with DMS3 control unit Supply voltage 230 V AC Terminal board connection Protection of the electromotor against overheating Switching off in limit positions from position and from thrust Adjustable switching-off thrust from 50% to 100% Thrust blocking in limit positions Thrust blocking during the [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-ulr-1-pa/">Electric linear actuator ULR 1 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4></h4>
<h4>ULR 1 PA &#8211; electric linear actuator</h4>
<p>&nbsp;</p>
<h3>Standard equipment and functions with DMS3 control unit</h3>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>Protection of the electromotor against overheating</li>
<li>Switching off in limit positions from position and from thrust</li>
<li>Adjustable switching-off thrust from 50% to 100%</li>
<li>Thrust blocking in limit positions</li>
<li>Thrust blocking during the start</li>
<li>2 freely programmable relays R1, R2 (Not valid for Profibus and Modbus)</li>
<li>Relay READY (Not valid for Profibus and Modbus)</li>
<li>Control by unified signal 0/4 &#8211; 20 mA, 4 &#8211; 12 mA, 12 &#8211; 20 mA, or 0/2 &#8211; 10 V (Not valid for Profibus and Modbus)</li>
<li>Control by permanent voltage (+24 V DC) &#8211; OPEN, CLOSE</li>
<li>Impulse control (inching duty) (+24 V DC) &#8211; OPEN, STOP, CLOSE</li>
<li>Timing mode / regime of operation</li>
<li>Safety function ESD (failure reaction)</li>
<li>Electronic position transmitter 4 to 20 mA passive (not for DMS3 in 2P version) (Not valid for Profibus and Modbus)</li>
<li>Auxiliary voltage output 24 V AC, max. 40 mA for supply of the control inputs</li>
<li>Output of failure messages</li>
<li>Space heater operated by control unit</li>
<li>Communication interface RS 232</li>
<li>Programme for parameterization setting a PC</li>
<li>Mechanical connection &#8211; pillars</li>
<li>Manual control</li>
<li>Enclosure protection IP 66</li>
</ul>
<h3>Additional equipment</h3>
<ul>
<li>Supply voltage 220 V, 3&#215;380 V, 3&#215;400 V, 120 V/60 Hz, 110 V/60 Hz</li>
<li>Local control for actuators with DMS 3 system</li>
<li>Reversing unit for 3-phase supply voltage</li>
<li>Additional relays RE3, RE4, RE5</li>
<li>Additional relay module RE1, RE2, RE3, RE4, RE5, READY</li>
<li>Version with control board PROFIBUS DP V0/V1</li>
<li>Version with control board MODBUS RTU</li>
<li>Communication cable DB-9F/RJ45</li>
<li>Mechanical connection according to ISO 5210 &#8211; flange size F07 (Y/55)</li>
<li>Mechanical connection according to ISO 5210 &#8211; flange size F10 (Y/70)</li>
<li>Enclosure protection IP 68</li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-ulr-1-pa/">Electric linear actuator ULR 1 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electric part-turn actuator SPR 2.4 PA</title>
		<link>https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-4-pa-kopia/</link>
					<comments>https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-4-pa-kopia/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Thu, 25 Jan 2024 14:39:35 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/?post_type=product&#038;p=11717</guid>

					<description><![CDATA[<p>SPR 2.4 PA &#8211; electric part-turn actuator &#160; Standard equipment and functions of the actuators with DMS3 Supply voltage 230 V AC Terminal board connection Protection of the motor against overheating Switching off in limit positions from the position or torque Adjustable switching off-torque from 50% to 100% Torque blocking in limit positions Torque blocking [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-4-pa-kopia/">Electric part-turn actuator SPR 2.4 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>SPR 2.4 PA &#8211; electric part-turn actuator</h2>
<p>&nbsp;</p>
<h2>Standard equipment and functions of the actuators with DMS3</h2>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>Protection of the motor against overheating</li>
<li>Switching off in limit positions from the position or torque</li>
<li>Adjustable switching off-torque from 50% to 100%</li>
<li>Torque blocking in limit positions</li>
<li>Torque blocking during the start</li>
<li>2 freely programmable relays R1, R2 (18 functions)</li>
<li>Relay READY</li>
<li>Control by unified signal 0/4 &#8211; 20 mA, 4 &#8211; 12 mA, 12 &#8211; 20 mA,<br />
or 0/2 &#8211; 10 V (not for DMS3 in 2P version)</li>
<li>Control voltage for remote control 24 V DC</li>
<li>Impulse control (inching duty)</li>
<li>Timing mode / regime of operation</li>
<li>Safety function ESD (failure reaction)</li>
<li>Electronic position transmitter 4-20 mA passive (not for DMS3 in 2P version)</li>
<li>Auxiliary voltage output 24 V DC, max. 40 mA for supply of the control inputs</li>
<li>Output for failure messages</li>
<li>Space heater operated by control unit</li>
<li>LED position indicator</li>
<li>Communication interface RS 232</li>
<li>Programme for parameters setting by PC</li>
<li>Mechanical stop ends</li>
<li>Mechanical connection &#8211; flange ISO 5211</li>
<li>Manual control</li>
</ul>
<h2>Additional equipment of actuator with DMS3</h2>
<ul>
<li>Local control for actuators with DMS3 system</li>
<li>Additional relays RE3, RE4, RE5</li>
<li>Additional relay module RE1, RE2, RE3, RE4, RE5, READY</li>
<li>Version with control board PROFIBUS DP V0/V1</li>
<li>Version with control board MODBUS RTU</li>
</ul>
<h2>Documents for downloads</h2>
<ul>
<li><a href="https://marvelpit.sk/wp-content/uploads/2016/05/Gen_cond-Rematic_sk-en-1.pdf" target="_blank" rel="noopener noreferrer">General conditions</a></li>
<li><a href="https://marvelpit.sk/wp-content/uploads/2024/01/SPR_2.4PA_sk-en.pdf" target="_blank" rel="noopener noreferrer">Technical data sheet</a></li>
<li><a href="https://marvelpit.sk/wp-content/uploads/2016/05/SPR_1PA-2.4PA_74107402_en.pdf" target="_blank" rel="noopener noreferrer">Installation instructions</a></li>
<li><a href="https://marvelpit.sk/wp-content/uploads/2016/05/DMS3_en.pdf" target="_blank" rel="noopener noreferrer">DMS 3 &#8211; Instraction</a></li>
<li><a href="https://marvelpit.sk/wp-content/uploads/2016/05/DMS3_RJ_74105302_en.pdf" target="_blank" rel="noopener noreferrer">Control unit &#8211; Instraction</a></li>
</ul>
<p>&nbsp;</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-4-pa-kopia/">Electric part-turn actuator SPR 2.4 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-4-pa-kopia/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electric part-turn actuator SPR 2.3 PA</title>
		<link>https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-3-pa/</link>
					<comments>https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-3-pa/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Thu, 25 Jan 2024 14:19:44 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/?post_type=product&#038;p=11699</guid>

					<description><![CDATA[<p>SPR 2.3 PA &#8211; electric part-turn actuator &#160; Standard equipment and functions of the actuators with DMS3 Supply voltage 230 V AC Terminal board connection Protection of the motor against overheating Switching off in limit positions from the position or torque Adjustable switching off-torque from 50% to 100% Torque blocking in limit positions Torque blocking [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-3-pa/">Electric part-turn actuator SPR 2.3 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>SPR 2.3 PA &#8211; electric part-turn actuator</h2>
<p>&nbsp;</p>
<h2>Standard equipment and functions of the actuators with DMS3</h2>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>Protection of the motor against overheating</li>
<li>Switching off in limit positions from the position or torque</li>
<li>Adjustable switching off-torque from 50% to 100%</li>
<li>Torque blocking in limit positions</li>
<li>Torque blocking during the start</li>
<li>2 freely programmable relays R1, R2 (18 functions)</li>
<li>Relay READY</li>
<li>Control by unified signal 0/4 &#8211; 20 mA, 4 &#8211; 12 mA, 12 &#8211; 20 mA,<br />
or 0/2 &#8211; 10 V (not for DMS3 in 2P version)</li>
<li>Control voltage for remote control 24 V DC</li>
<li>Impulse control (inching duty)</li>
<li>Timing mode / regime of operation</li>
<li>Safety function ESD (failure reaction)</li>
<li>Electronic position transmitter 4-20 mA passive (not for DMS3 in 2P version)</li>
<li>Auxiliary voltage output 24 V DC, max. 40 mA for supply of the control inputs</li>
<li>Output for failure messages</li>
<li>Space heater operated by control unit</li>
<li>LED position indicator</li>
<li>Communication interface RS 232</li>
<li>Programme for parameters setting by PC</li>
<li>Mechanical stop ends</li>
<li>Mechanical connection &#8211; flange ISO 5211</li>
<li>Manual control</li>
</ul>
<h2>Additional equipment of actuator with DMS3</h2>
<ul>
<li>Local control for actuators with DMS3 system</li>
<li>Additional relays RE3, RE4, RE5</li>
<li>Additional relay module RE1, RE2, RE3, RE4, RE5, READY</li>
<li>Version with control board PROFIBUS DP V0/V1</li>
<li>Version with control board MODBUS RTU</li>
</ul>
<p>&nbsp;</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-3-pa/">Electric part-turn actuator SPR 2.3 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-3-pa/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electric part-turn actuator SPR 2 PA</title>
		<link>https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-pa/</link>
					<comments>https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-pa/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Thu, 25 Jan 2024 13:37:50 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/?post_type=product&#038;p=11684</guid>

					<description><![CDATA[<p>SPR 2 PA &#8211; electric part-turn actuator &#160; Standard equipment and functions of the actuators with DMS3 Supply voltage 230 V AC Terminal board connection Protection of the motor against overheating Switching off in limit positions from the position or torque Adjustable switching off-torque from 50% to 100% Torque blocking in limit positions Torque blocking [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-pa/">Electric part-turn actuator SPR 2 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>SPR 2 PA &#8211; electric part-turn actuator</h2>
<p>&nbsp;</p>
<h2>Standard equipment and functions of the actuators with DMS3</h2>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>Protection of the motor against overheating</li>
<li>Switching off in limit positions from the position or torque</li>
<li>Adjustable switching off-torque from 50% to 100%</li>
<li>Torque blocking in limit positions</li>
<li>Torque blocking during the start</li>
<li>2 freely programmable relays R1, R2 (18 functions)</li>
<li>Relay READY</li>
<li>Control by unified signal 0/4 &#8211; 20 mA, 4 &#8211; 12 mA, 12 &#8211; 20 mA,<br />
or 0/2 &#8211; 10 V (not for DMS3 in 2P version)</li>
<li>Control voltage for remote control 24 V DC</li>
<li>Impulse control (inching duty)</li>
<li>Timing mode / regime of operation</li>
<li>Safety function ESD (failure reaction)</li>
<li>Electronic position transmitter 4-20 mA passive (not for DMS3 in 2P version)</li>
<li>Auxiliary voltage output 24 V DC, max. 40 mA for supply of the control inputs</li>
<li>Output for failure messages</li>
<li>Space heater operated by control unit</li>
<li>LED position indicator</li>
<li>Communication interface RS 232</li>
<li>Programme for parameters setting by PC</li>
<li>Mechanical stop ends</li>
<li>Mechanical connection &#8211; flange ISO 5211</li>
<li>Manual control</li>
</ul>
<h2>Additional equipment of actuator with DMS3</h2>
<ul>
<li>Local control for actuators with DMS3 system</li>
<li>Additional relays RE3, RE4, RE5</li>
<li>Additional relay module RE1, RE2, RE3, RE4, RE5, READY</li>
<li>Version with control board PROFIBUS DP V0/V1</li>
<li>Version with control board MODBUS RTU</li>
</ul>
<p>&nbsp;</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-pa/">Electric part-turn actuator SPR 2 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-part-turn-actuator-spr-2-pa/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Explosion-proof electric multi-turn actuator MO 4-Ex</title>
		<link>https://marvelpit.sk/en/product/explosion-proof-electric-multi-turn-actuator-mo-4-ex/</link>
					<comments>https://marvelpit.sk/en/product/explosion-proof-electric-multi-turn-actuator-mo-4-ex/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 03 Dec 2018 13:00:51 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/?post_type=product&#038;p=10153</guid>

					<description><![CDATA[<p>MO 4-Ex &#8211; explosion-proof electric multi-turn actuator &#160; Standard equipment Supply voltage 3&#215;400 V AC Terminal board connection 2 torque switches 2 position switches 2 additional position switches Space heater with thermal switch Mechanical connection &#8211; flange Mechanical position indicator Manual control Torque switches blocking in limit position Additional equipment Supply voltage 3&#215;380 V AC [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/explosion-proof-electric-multi-turn-actuator-mo-4-ex/">Explosion-proof electric multi-turn actuator MO 4-Ex</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>MO 4-Ex &#8211; explosion-proof electric multi-turn actuator</h2>
<p>&nbsp;</p>
<h2>Standard equipment</h2>
<ul>
<li>Supply voltage 3&#215;400 V AC</li>
<li>Terminal board connection</li>
<li>2 torque switches</li>
<li>2 position switches</li>
<li>2 additional position switches</li>
<li>Space heater with thermal switch</li>
<li>Mechanical connection &#8211; flange</li>
<li>Mechanical position indicator</li>
<li>Manual control</li>
<li>Torque switches blocking in limit position</li>
</ul>
<h2>Additional equipment</h2>
<ul>
<li>Supply voltage 3&#215;380 V AC</li>
<li>Tandem switches</li>
<li>Transmitter:<br />
&#8211; potentiometer: 1&#215;100 Ω, 1&#215;2000 Ω, 2&#215;100 Ω, 2&#215;2000 Ω<br />
&#8211; electronic position transmitter 0/4 &#8211; 20 mA, (passive/active)<br />
&#8211; CPT (capacitive) 4 &#8211; 20 mA, (passive/active)</li>
<li>Mechanical connection:<br />
&#8211; ISO 5210, shape A, B2, B3, B4<br />
&#8211; DIN 3338, shape C<br />
&#8211; other non-standard connection</li>
</ul>
<p>&nbsp;</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/explosion-proof-electric-multi-turn-actuator-mo-4-ex/">Explosion-proof electric multi-turn actuator MO 4-Ex</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/explosion-proof-electric-multi-turn-actuator-mo-4-ex/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electric multi-turn actuator MO 4</title>
		<link>https://marvelpit.sk/en/product/electric-multi-turn-actuator-mo-4-to-500-nm/</link>
					<comments>https://marvelpit.sk/en/product/electric-multi-turn-actuator-mo-4-to-500-nm/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 03 Dec 2018 12:10:54 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/?post_type=product&#038;p=10131</guid>

					<description><![CDATA[<p>MO 4 &#8211; electric multi-turn actuator &#160; Standard equipment Supply voltage 3&#215;400 V AC Protection of the motor against overheating Terminal board connection 2 torgue switches 2 position switches 2 additional position switches Space heater with thermal switch Mechanical connection ISO 5210 &#8211; flange F14 / shape B2, B3, B4, C Mechanical position indicator Torque [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-multi-turn-actuator-mo-4-to-500-nm/">Electric multi-turn actuator MO 4</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>MO 4 &#8211; electric multi-turn actuator</h2>
<p>&nbsp;</p>
<h2>Standard equipment</h2>
<ul>
<li>Supply voltage 3&#215;400 V AC</li>
<li>Protection of the motor against overheating</li>
<li>Terminal board connection</li>
<li>2 torgue switches</li>
<li>2 position switches</li>
<li>2 additional position switches</li>
<li>Space heater with thermal switch</li>
<li>Mechanical connection ISO 5210 &#8211; flange F14 / shape B2, B3, B4, C</li>
<li>Mechanical position indicator</li>
<li>Torque switches blocking in limit position</li>
<li>Manual control</li>
<li>Protection enclosure IP 55</li>
</ul>
<h2>Additional equipment</h2>
<ul>
<li>Supply voltage 3&#215;380 V AC</li>
<li>Connector connection</li>
<li>Tandem switches</li>
<li>Transmitter:<br />
&#8211; potentiometer: 1&#215;100 Ω, 1&#215;2000 Ω, 2&#215;100 Ω, 2&#215;2000 Ω<br />
&#8211; electronic position transmitter 0/4 &#8211; 20 mA, (passive/active)<br />
&#8211; CPT (capacitive) 4 &#8211; 20 mA, (passive/active)</li>
<li>Local control</li>
<li>Mechanical connection:<br />
&#8211; ISO 5210, shape A, B1, D and ГОСТ Р 55510 &#8211; Б<br />
&#8211; other non-standard connection</li>
<li>Protection enclosure IP 67</li>
<li>Ambient temperature -50 to +40 °C</li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-multi-turn-actuator-mo-4-to-500-nm/">Electric multi-turn actuator MO 4</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-multi-turn-actuator-mo-4-to-500-nm/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electric part-turn actuator UP 1</title>
		<link>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-1/</link>
					<comments>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-1/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 03 Dec 2018 09:57:40 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/?post_type=product&#038;p=10119</guid>

					<description><![CDATA[<p>UP 1 &#8211; electric part-turn actuator &#160; Standard equipment Supply voltage 230 V AC Terminal board connection 2 torque switches 2 position switches 2 additional position switches Mechanical connection ISO 5211 Space heater with thermal switch Thermal protection of motor Local position indicator Manual control Additional equipment Supply voltage 3&#215;400 V AC Connector connection Transmitter: [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-up-1/">Electric part-turn actuator UP 1</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>UP 1 &#8211; electric part-turn actuator</h2>
<p>&nbsp;</p>
<h2>Standard equipment</h2>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>2 torque switches</li>
<li>2 position switches</li>
<li>2 additional position switches</li>
<li>Mechanical connection ISO 5211</li>
<li>Space heater with thermal switch</li>
<li>Thermal protection of motor</li>
<li>Local position indicator</li>
<li>Manual control</li>
</ul>
<h2>Additional equipment</h2>
<ul>
<li>Supply voltage 3&#215;400 V AC</li>
<li>Connector connection</li>
<li>Transmitter:<br />
&#8211; potentiometer: 1&#215;100 Ω, 1&#215;2000 Ω, 2&#215;100 Ω, 2&#215;2000 Ω<br />
&#8211; electronic position transmitter 0/4 &#8211; 20 mA, (passive/active)<br />
&#8211; CPT (capacitive) 4 &#8211; 20 mA, (passive/active)</li>
<li>Gold coated microswitch contacts</li>
<li>Electric local control</li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-up-1/">Electric part-turn actuator UP 1</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-1/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electric part-turn actuator SP MIKRO</title>
		<link>https://marvelpit.sk/en/product/electric-part-turn-actuator-sp-mikro/</link>
					<comments>https://marvelpit.sk/en/product/electric-part-turn-actuator-sp-mikro/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 03 Dec 2018 08:51:24 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/?post_type=product&#038;p=10095</guid>

					<description><![CDATA[<p>SP MIKRO &#8211; electric part-turn actuator &#160; Standard equipment Supply voltage 24 V AC Electrical cable connection 2 position switches Mechanical connection ISO 5211 &#8211; flange F04 Additional equipment Supply voltage 220/230 V AC, 24 V DC 2 additional position switches Transmitter: &#8211; potentiometer: 1&#215;100 Ω, 1&#215;1000 Ω, 1&#215;2000 Ω &#8211; electronic position transmitter 0/4 [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-sp-mikro/">Electric part-turn actuator SP MIKRO</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2><em>SP MIKRO &#8211; electric part-turn actuator</em></h2>
<p>&nbsp;</p>
<h2>Standard equipment</h2>
<ul>
<li>Supply voltage 24 V AC</li>
<li>Electrical cable connection</li>
<li>2 position switches</li>
<li>Mechanical connection ISO 5211 &#8211; flange F04</li>
</ul>
<h2>Additional equipment</h2>
<ul>
<li>Supply voltage 220/230 V AC, 24 V DC</li>
<li>2 additional position switches</li>
<li>Transmitter:<br />
&#8211; potentiometer: 1&#215;100 Ω, 1&#215;1000 Ω, 1&#215;2000 Ω<br />
&#8211; electronic position transmitter 0/4 &#8211; 20 mA, (passive/active)</li>
</ul>
<p>&nbsp;</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-sp-mikro/">Electric part-turn actuator SP MIKRO</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-part-turn-actuator-sp-mikro/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electric part-turn actuator UP 2.5</title>
		<link>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2-5/</link>
					<comments>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2-5/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Fri, 09 Feb 2018 13:19:04 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/?post_type=product&#038;p=9543</guid>

					<description><![CDATA[<p>UP 2.5 &#8211; electric part-turn actuator &#160; Standard equipment Supply voltage 230 V AC Terminal board connection 2 torque switches 2 position switches 2 additional position switches Mechanical connection ISO 5211 Space heater with thermal switch Thermal protection of motor Local position indicator Manual control Additional equipment Supply voltage 3&#215;400 V AC, 110 V AC/60 [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2-5/">Electric part-turn actuator UP 2.5</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>UP 2.5 &#8211; electric part-turn actuator</h2>
<p>&nbsp;</p>
<h2>Standard equipment</h2>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>2 torque switches</li>
<li>2 position switches</li>
<li>2 additional position switches</li>
<li>Mechanical connection ISO 5211</li>
<li>Space heater with thermal switch</li>
<li>Thermal protection of motor</li>
<li>Local position indicator</li>
<li>Manual control</li>
</ul>
<h2>Additional equipment</h2>
<ul>
<li>Supply voltage 3&#215;400 V AC, 110 V AC/60 Hz, 120 V AC/60 Hz</li>
<li>Connector connection</li>
<li>Reverse unit</li>
<li>Transmitter:<br />
&#8211; potentiometer: 1&#215;100 Ω, 1&#215;2000 Ω, 2&#215;100 Ω, 2&#215;2000 Ω<br />
&#8211; electronic position transmitter 0/4 &#8211; 20 mA, (passive/active)<br />
&#8211; CPT (capacitive) 4 &#8211; 20 mA, (passive/active)</li>
<li>Gold coated microswitch contacts</li>
<li>Electric local control</li>
</ul>
<p>&nbsp;</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2-5/">Electric part-turn actuator UP 2.5</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2-5/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>