<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Unimact Archives - MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</title>
	<atom:link href="https://marvelpit.sk/en/typ-konstrukcie/unimact-en/feed/" rel="self" type="application/rss+xml" />
	<link>https://marvelpit.sk/en/typ-konstrukcie/unimact-en/</link>
	<description>Central european business company Marvel - Electric actuators, Valves</description>
	<lastBuildDate>Mon, 06 Oct 2025 13:57:28 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://marvelpit.sk/wp-content/uploads/2018/08/cropped-marvel_logo_4_1-32x32.png</url>
	<title>Unimact Archives - MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</title>
	<link>https://marvelpit.sk/en/typ-konstrukcie/unimact-en/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Electric linear actuator ULR 2 PA</title>
		<link>https://marvelpit.sk/en/product/electric-linear-actuator-ulr-2-pa/</link>
		
		<dc:creator><![CDATA[tomas.lescisin@marvelpit.sk]]></dc:creator>
		<pubDate>Wed, 24 Sep 2025 14:46:22 +0000</pubDate>
				<guid isPermaLink="false">https://marvelpit.sk/?post_type=product&#038;p=13296</guid>

					<description><![CDATA[<p>ULR 2 PA &#8211; electric linear actuator &#160; Standard equipment and functions with DMS3 control unit Supply voltage 230 V AC Terminal board connection Protection of the electromotor against overheating Switching off in limit positions from position and from thrust Adjustable switching-off thrust from 50% to 100% Thrust blocking in limit positions Thrust blocking during the [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-ulr-2-pa/">Electric linear actuator ULR 2 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4></h4>
<h4>ULR 2 PA &#8211; electric linear actuator</h4>
<p>&nbsp;</p>
<h3>Standard equipment and functions with DMS3 control unit</h3>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>Protection of the electromotor against overheating</li>
<li>Switching off in limit positions from position and from thrust</li>
<li>Adjustable switching-off thrust from 50% to 100%</li>
<li>Thrust blocking in limit positions</li>
<li>Thrust blocking during the start</li>
<li>2 freely programmable relays R1, R2 (Not valid for Profibus and Modbus)</li>
<li>Relay READY (Not valid for Profibus and Modbus)</li>
<li>Control by unified signal 0/4 &#8211; 20 mA, 4 &#8211; 12 mA, 12 &#8211; 20 mA, or 0/2 &#8211; 10 V (Not valid for Profibus and Modbus)</li>
<li>Control by permanent voltage (+24 V DC) &#8211; OPEN, CLOSE</li>
<li>Impulse control (inching duty) (+24 V DC) &#8211; OPEN, STOP, CLOSE</li>
<li>Timing mode / regime of operation</li>
<li>Safety function ESD (failure reaction)</li>
<li>Electronic position transmitter 4 to 20 mA passive (not for DMS3 in 2P version) (Not valid for Profibus and Modbus)</li>
<li>Auxiliary voltage output 24 V AC, max. 40 mA for supply of the control inputs</li>
<li>Output of failure messages</li>
<li>Space heater operated by control unit</li>
<li>Communication interface RS 232</li>
<li>Programme for parameterization setting a PC</li>
<li>Mechanical connection &#8211; pillars</li>
<li>Manual control</li>
<li>Enclosure protection IP 66</li>
</ul>
<h3>Additional equipment</h3>
<ul>
<li>Supply voltage 220 V, 3&#215;380 V, 3&#215;400 V, 120 V/60 Hz, 110 V/60 Hz</li>
<li>Local control for actuators with DMS 3 system</li>
<li>Reversing unit for 3-phase supply voltage</li>
<li>Additional relays RE3, RE4, RE5</li>
<li>Additional relay module RE1, RE2, RE3, RE4, RE5, READY</li>
<li>Version with control board PROFIBUS DP V0/V1</li>
<li>Version with control board MODBUS RTU</li>
<li>Communication cable DB-9F/RJ45</li>
<li>Mechanical connection according to ISO 5210 &#8211; flange size F07</li>
<li>Mechanical connection according to ISO 5210 &#8211; flange size F10</li>
<li>Enclosure protection IP 68</li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-ulr-2-pa/">Electric linear actuator ULR 2 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electric linear actuator ULR 1 PA</title>
		<link>https://marvelpit.sk/en/product/electric-linear-actuator-ulr-1-pa/</link>
		
		<dc:creator><![CDATA[tomas.lescisin@marvelpit.sk]]></dc:creator>
		<pubDate>Tue, 23 Sep 2025 10:30:55 +0000</pubDate>
				<guid isPermaLink="false">https://marvelpit.sk/?post_type=product&#038;p=13283</guid>

					<description><![CDATA[<p>ULR 1 PA &#8211; electric linear actuator &#160; Standard equipment and functions with DMS3 control unit Supply voltage 230 V AC Terminal board connection Protection of the electromotor against overheating Switching off in limit positions from position and from thrust Adjustable switching-off thrust from 50% to 100% Thrust blocking in limit positions Thrust blocking during the [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-ulr-1-pa/">Electric linear actuator ULR 1 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4></h4>
<h4>ULR 1 PA &#8211; electric linear actuator</h4>
<p>&nbsp;</p>
<h3>Standard equipment and functions with DMS3 control unit</h3>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>Protection of the electromotor against overheating</li>
<li>Switching off in limit positions from position and from thrust</li>
<li>Adjustable switching-off thrust from 50% to 100%</li>
<li>Thrust blocking in limit positions</li>
<li>Thrust blocking during the start</li>
<li>2 freely programmable relays R1, R2 (Not valid for Profibus and Modbus)</li>
<li>Relay READY (Not valid for Profibus and Modbus)</li>
<li>Control by unified signal 0/4 &#8211; 20 mA, 4 &#8211; 12 mA, 12 &#8211; 20 mA, or 0/2 &#8211; 10 V (Not valid for Profibus and Modbus)</li>
<li>Control by permanent voltage (+24 V DC) &#8211; OPEN, CLOSE</li>
<li>Impulse control (inching duty) (+24 V DC) &#8211; OPEN, STOP, CLOSE</li>
<li>Timing mode / regime of operation</li>
<li>Safety function ESD (failure reaction)</li>
<li>Electronic position transmitter 4 to 20 mA passive (not for DMS3 in 2P version) (Not valid for Profibus and Modbus)</li>
<li>Auxiliary voltage output 24 V AC, max. 40 mA for supply of the control inputs</li>
<li>Output of failure messages</li>
<li>Space heater operated by control unit</li>
<li>Communication interface RS 232</li>
<li>Programme for parameterization setting a PC</li>
<li>Mechanical connection &#8211; pillars</li>
<li>Manual control</li>
<li>Enclosure protection IP 66</li>
</ul>
<h3>Additional equipment</h3>
<ul>
<li>Supply voltage 220 V, 3&#215;380 V, 3&#215;400 V, 120 V/60 Hz, 110 V/60 Hz</li>
<li>Local control for actuators with DMS 3 system</li>
<li>Reversing unit for 3-phase supply voltage</li>
<li>Additional relays RE3, RE4, RE5</li>
<li>Additional relay module RE1, RE2, RE3, RE4, RE5, READY</li>
<li>Version with control board PROFIBUS DP V0/V1</li>
<li>Version with control board MODBUS RTU</li>
<li>Communication cable DB-9F/RJ45</li>
<li>Mechanical connection according to ISO 5210 &#8211; flange size F07 (Y/55)</li>
<li>Mechanical connection according to ISO 5210 &#8211; flange size F10 (Y/70)</li>
<li>Enclosure protection IP 68</li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-ulr-1-pa/">Electric linear actuator ULR 1 PA</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electric part-turn actuator UP 1</title>
		<link>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-1/</link>
					<comments>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-1/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 03 Dec 2018 09:57:40 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/?post_type=product&#038;p=10119</guid>

					<description><![CDATA[<p>UP 1 &#8211; electric part-turn actuator &#160; Standard equipment Supply voltage 230 V AC Terminal board connection 2 torque switches 2 position switches 2 additional position switches Mechanical connection ISO 5211 Space heater with thermal switch Thermal protection of motor Local position indicator Manual control Additional equipment Supply voltage 3&#215;400 V AC Connector connection Transmitter: [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-up-1/">Electric part-turn actuator UP 1</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>UP 1 &#8211; electric part-turn actuator</h2>
<p>&nbsp;</p>
<h2>Standard equipment</h2>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>2 torque switches</li>
<li>2 position switches</li>
<li>2 additional position switches</li>
<li>Mechanical connection ISO 5211</li>
<li>Space heater with thermal switch</li>
<li>Thermal protection of motor</li>
<li>Local position indicator</li>
<li>Manual control</li>
</ul>
<h2>Additional equipment</h2>
<ul>
<li>Supply voltage 3&#215;400 V AC</li>
<li>Connector connection</li>
<li>Transmitter:<br />
&#8211; potentiometer: 1&#215;100 Ω, 1&#215;2000 Ω, 2&#215;100 Ω, 2&#215;2000 Ω<br />
&#8211; electronic position transmitter 0/4 &#8211; 20 mA, (passive/active)<br />
&#8211; CPT (capacitive) 4 &#8211; 20 mA, (passive/active)</li>
<li>Gold coated microswitch contacts</li>
<li>Electric local control</li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-up-1/">Electric part-turn actuator UP 1</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-1/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electric part-turn actuator UP 2.5</title>
		<link>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2-5/</link>
					<comments>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2-5/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Fri, 09 Feb 2018 13:19:04 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/?post_type=product&#038;p=9543</guid>

					<description><![CDATA[<p>UP 2.5 &#8211; electric part-turn actuator &#160; Standard equipment Supply voltage 230 V AC Terminal board connection 2 torque switches 2 position switches 2 additional position switches Mechanical connection ISO 5211 Space heater with thermal switch Thermal protection of motor Local position indicator Manual control Additional equipment Supply voltage 3&#215;400 V AC, 110 V AC/60 [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2-5/">Electric part-turn actuator UP 2.5</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>UP 2.5 &#8211; electric part-turn actuator</h2>
<p>&nbsp;</p>
<h2>Standard equipment</h2>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>2 torque switches</li>
<li>2 position switches</li>
<li>2 additional position switches</li>
<li>Mechanical connection ISO 5211</li>
<li>Space heater with thermal switch</li>
<li>Thermal protection of motor</li>
<li>Local position indicator</li>
<li>Manual control</li>
</ul>
<h2>Additional equipment</h2>
<ul>
<li>Supply voltage 3&#215;400 V AC, 110 V AC/60 Hz, 120 V AC/60 Hz</li>
<li>Connector connection</li>
<li>Reverse unit</li>
<li>Transmitter:<br />
&#8211; potentiometer: 1&#215;100 Ω, 1&#215;2000 Ω, 2&#215;100 Ω, 2&#215;2000 Ω<br />
&#8211; electronic position transmitter 0/4 &#8211; 20 mA, (passive/active)<br />
&#8211; CPT (capacitive) 4 &#8211; 20 mA, (passive/active)</li>
<li>Gold coated microswitch contacts</li>
<li>Electric local control</li>
</ul>
<p>&nbsp;</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2-5/">Electric part-turn actuator UP 2.5</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2-5/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electric part-turn actuator UP 2.4</title>
		<link>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2-4/</link>
					<comments>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2-4/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Fri, 09 Feb 2018 12:42:10 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/?post_type=product&#038;p=9527</guid>

					<description><![CDATA[<p>UP 2.4 – electric part-turn actuator &#160; Standard equipment Supply voltage 230 V AC Terminal board connection 2 torque switches 2 position switches 2 additional position switches Mechanical connection ISO 5211 Space heater with thermal switch Thermal protection of motor Local position indicator Manual control Additional equipment Supply voltage 3&#215;400 V AC, 110 V AC/60 [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2-4/">Electric part-turn actuator UP 2.4</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>UP 2.4 – electric part-turn actuator</h2>
<p>&nbsp;</p>
<h2>Standard equipment</h2>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>2 torque switches</li>
<li>2 position switches</li>
<li>2 additional position switches</li>
<li>Mechanical connection ISO 5211</li>
<li>Space heater with thermal switch</li>
<li>Thermal protection of motor</li>
<li>Local position indicator</li>
<li>Manual control</li>
</ul>
<h2>Additional equipment</h2>
<ul>
<li>Supply voltage 3&#215;400 V AC, 110 V AC/60 Hz, 120 V AC/60 Hz</li>
<li>Connector connection</li>
<li>Reverse unit</li>
<li>Transmitter:<br />
&#8211; potentiometer: 1&#215;100 Ω, 1&#215;2000 Ω, 2&#215;100 Ω, 2&#215;2000 Ω<br />
&#8211; electronic position transmitter 0/4 &#8211; 20 mA, (passive/active)<br />
&#8211; CPT (capacitive) 4 &#8211; 20 mA, (passive/active)</li>
<li>Gold coated microswitch contacts</li>
<li>Electric local control</li>
</ul>
<h2>Documents for downloads</h2>
<ul>
<li><a href="https://marvelpit.sk/wp-content/uploads/2018/12/Gen_cond-Standard_sk-en-3.pdf" target="_blank" rel="noopener noreferrer">General conditions</a></li>
<li><a href="https://marvelpit.sk/wp-content/uploads/2018/02/UP_2.4_sk-en-1.pdf" target="_blank" rel="noopener noreferrer">Technical data sheet</a></li>
<li><a href="https://marvelpit.sk/wp-content/uploads/2018/12/UPX_74098402_en.pdf" target="_blank" rel="noopener noreferrer">Installation instructions</a></li>
</ul>
<p>&nbsp;</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2-4/">Electric part-turn actuator UP 2.4</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2-4/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electric part-turn actuator UP 2</title>
		<link>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2/</link>
					<comments>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Fri, 09 Feb 2018 12:07:43 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/?post_type=product&#038;p=9507</guid>

					<description><![CDATA[<p>UP 2 &#8211; electric part-turn actuator &#160; Standard equipment Supply voltage 230 V AC Terminal board connection 2 torque switches 2 position switches 2 additional position switches Mechanical connection ISO 5211 Space heater with thermal switch Thermal protection of motor Local position indicator Manual control Additional equipment Supply voltage 3&#215;400 V AC, 110 V AC/60 [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2/">Electric part-turn actuator UP 2</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>UP 2 &#8211; electric part-turn actuator</h2>
<p>&nbsp;</p>
<h2>Standard equipment</h2>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>2 torque switches</li>
<li>2 position switches</li>
<li>2 additional position switches</li>
<li>Mechanical connection ISO 5211</li>
<li>Space heater with thermal switch</li>
<li>Thermal protection of motor</li>
<li>Local position indicator</li>
<li>Manual control</li>
</ul>
<h2>Additional equipment</h2>
<ul>
<li>Supply voltage 3&#215;400 V AC, 110 V AC/60 Hz, 120 V AC/60 Hz</li>
<li>Connector connection</li>
<li>Reverse unit</li>
<li>Transmitter:<br />
&#8211; potentiometer: 1&#215;100 Ω, 1&#215;2000 Ω, 2&#215;100 Ω, 2&#215;2000 Ω<br />
&#8211; electronic position transmitter 0/4 &#8211; 20 mA, (passive/active)<br />
&#8211; CPT (capacitive) 4 &#8211; 20 mA, (passive/active)</li>
<li>Gold coated microswitch contacts</li>
<li>Electric local control</li>
</ul>
<h2>Documents for downloads</h2>
<ul>
<li><a href="https://marvelpit.sk/wp-content/uploads/2018/12/Gen_cond-Standard_sk-en-3.pdf" target="_blank" rel="noopener noreferrer">General conditions</a></li>
<li><a href="https://marvelpit.sk/wp-content/uploads/2018/02/UP_2_sk-en-1.pdf" target="_blank" rel="noopener noreferrer">Technical data sheet</a></li>
<li><a href="https://marvelpit.sk/wp-content/uploads/2018/12/UPX_74098402_en.pdf" target="_blank" rel="noopener noreferrer">Installation instructions</a></li>
</ul>
<p>&nbsp;</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2/">Electric part-turn actuator UP 2</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-part-turn-actuator-up-2/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electric linear actuator UL 2-A</title>
		<link>https://marvelpit.sk/en/product/electric-linear-actuator-ul-2-a/</link>
					<comments>https://marvelpit.sk/en/product/electric-linear-actuator-ul-2-a/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 23 May 2016 11:19:50 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/produkty/electric-linear-actuator-ul-2-a/</guid>

					<description><![CDATA[<p>UL 2-A &#8211; electric linear actuator &#160; Standard equipment Supply voltage 230 V AC Terminal board connection 2 thrust switches 2 position switches 2 additional position switches Space heater with thermal switch Mechanical connection &#8211; pillars Manual control Mechanical position indicator Additional equipment Supply voltage 3&#215;400 V AC Transmitter: &#8211; potentiometer: 1&#215;100 Ω, 1&#215;2000 Ω, [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-ul-2-a/">Electric linear actuator UL 2-A</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>UL 2-A &#8211; electric linear actuator</h2>
<p>&nbsp;</p>
<h2>Standard equipment</h2>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>2 thrust switches</li>
<li>2 position switches</li>
<li>2 additional position switches</li>
<li>Space heater with thermal switch</li>
<li>Mechanical connection &#8211; pillars</li>
<li>Manual control</li>
<li>Mechanical position indicator</li>
</ul>
<h2>Additional equipment</h2>
<ul>
<li>Supply voltage 3&#215;400 V AC</li>
<li>Transmitter:<br />
&#8211; potentiometer: 1&#215;100 Ω, 1&#215;2000 Ω, 2&#215;100 Ω, 2&#215;2000 Ω<br />
&#8211; electronic position transmitter 0/4 &#8211; 20 mA, (passive/active)<br />
&#8211; CPT (capacitive) 4 &#8211; 20 mA, (passive/active)</li>
</ul>
<h2>Documents for download</h2>
<ul>
<li><a href="https://marvelpit.sk/wp-content/uploads/2016/10/Gen_cond-Atom_sk-en.pdf" target="_blank" rel="noopener noreferrer">General conditions</a></li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-ul-2-a/">Electric linear actuator UL 2-A</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-linear-actuator-ul-2-a/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electric linear actuator UL 1-A</title>
		<link>https://marvelpit.sk/en/product/electric-linear-actuator-ul-1-a/</link>
					<comments>https://marvelpit.sk/en/product/electric-linear-actuator-ul-1-a/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 23 May 2016 10:27:51 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/produkty/electric-linear-actuator-ul-1-a/</guid>

					<description><![CDATA[<p>UL 1-A &#8211; electric linear actuator &#160; Standard equipment Supply voltage 230 V AC Terminal board connection 2 thrust switches 2 position switches 2 additional position switches Space heater with thermal switch Mechanical connection &#8211; pillars Manual control Mechanical position indicator Additional equipment Supply voltage 3&#215;400 V AC Transmitter: &#8211; potentiometer: 1&#215;100 Ω, 1&#215;2000 Ω, [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-ul-1-a/">Electric linear actuator UL 1-A</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>UL 1-A &#8211; electric linear actuator</h2>
<p>&nbsp;</p>
<h2>Standard equipment</h2>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>2 thrust switches</li>
<li>2 position switches</li>
<li>2 additional position switches</li>
<li>Space heater with thermal switch</li>
<li>Mechanical connection &#8211; pillars</li>
<li>Manual control</li>
<li>Mechanical position indicator</li>
</ul>
<h2>Additional equipment</h2>
<ul>
<li>Supply voltage 3&#215;400 V AC</li>
<li>Transmitter:<br />
&#8211; potentiometer: 1&#215;100 Ω, 1&#215;2000 Ω, 2&#215;100 Ω, 2&#215;2000 Ω<br />
&#8211; electronic position transmitter 0/4 &#8211; 20 mA, (passive/active)<br />
&#8211; CPT (capacitive) 4 &#8211; 20 mA, (passive/active)</li>
</ul>
<h2>Documents for download</h2>
<ul>
<li><a href="https://marvelpit.sk/wp-content/uploads/2016/10/Gen_cond-Atom_sk-en.pdf" target="_blank" rel="noopener noreferrer">General conditions</a></li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-ul-1-a/">Electric linear actuator UL 1-A</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-linear-actuator-ul-1-a/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electric linear actuator UL 0-A</title>
		<link>https://marvelpit.sk/en/product/electric-linear-actuator-ul-0-a/</link>
					<comments>https://marvelpit.sk/en/product/electric-linear-actuator-ul-0-a/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 23 May 2016 10:24:21 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/produkty/electric-linear-actuator-ul-0-a/</guid>

					<description><![CDATA[<p>UL 0-A &#8211; Electric linear actuator &#160; Standard equipment Supply voltage 230 V AC Terminal board connection 2 thrust switches 2 position switches 2 additional position switches Space heater with thermal switch Mechanical connection &#8211; pillars Manual control Mechanical position indicator Additional equipment Transmitter: &#8211; potentiometer: 1&#215;100 Ω, 1&#215;2000 Ω, 2&#215;100 Ω, 2&#215;2000 Ω &#8211; [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-ul-0-a/">Electric linear actuator UL 0-A</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2></h2>
<h2>UL 0-A &#8211; Electric linear actuator</h2>
<p>&nbsp;</p>
<h2>Standard equipment</h2>
<ul>
<li>Supply voltage 230 V AC</li>
<li>Terminal board connection</li>
<li>2 thrust switches</li>
<li>2 position switches</li>
<li>2 additional position switches</li>
<li>Space heater with thermal switch</li>
<li>Mechanical connection &#8211; pillars</li>
<li>Manual control</li>
<li>Mechanical position indicator</li>
</ul>
<h2>Additional equipment</h2>
<ul>
<li>Transmitter:<br />
&#8211; potentiometer: 1&#215;100 Ω, 1&#215;2000 Ω, 2&#215;100 Ω, 2&#215;2000 Ω<br />
&#8211; electronic position transmitter 0/4 &#8211; 20 mA, (passive/active)<br />
&#8211; DCPT transmitter 4 &#8211; 20 mA, (passive/active)</li>
</ul>
<h2>Documents for download</h2>
<ul>
<li><a href="https://marvelpit.sk/wp-content/uploads/2016/10/Gen_cond-Atom_sk-en.pdf" target="_blank" rel="noopener noreferrer">General conditions</a></li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/electric-linear-actuator-ul-0-a/">Electric linear actuator UL 0-A</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/electric-linear-actuator-ul-0-a/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Explosion-proof electric linear actuator ULR 2 PA-Ex</title>
		<link>https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-ulr-2-pa-ex/</link>
					<comments>https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-ulr-2-pa-ex/#respond</comments>
		
		<dc:creator><![CDATA[redwolf]]></dc:creator>
		<pubDate>Mon, 23 May 2016 10:15:19 +0000</pubDate>
				<guid isPermaLink="false">https://new.marvelpit.sk/produkty/electric-linear-actuator-ulr-2pa-ex/</guid>

					<description><![CDATA[<p>ULR 2 PA-Ex &#8211; explosion-proof electric linear actuator &#160; Standard equipment and functions with DMS3 control unit Supply voltage: 230 V / 50 Hz Terminal board connection Protection of the electromotor against overheating Switching off in limit positions from position and from thrust Adjustable switching-off thrust from 50% to 100% Thrust blocking in limit positions [&#8230;]</p>
<p>Príspevok <a href="https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-ulr-2-pa-ex/">Explosion-proof electric linear actuator ULR 2 PA-Ex</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4></h4>
<h4>ULR 2 PA-Ex &#8211; explosion-proof electric linear actuator</h4>
<p>&nbsp;</p>
<h3>Standard equipment and functions with DMS3 control unit</h3>
<ul>
<li>Supply voltage:
<ul>
<li>230 V / 50 Hz</li>
</ul>
</li>
<li>Terminal board connection</li>
<li>Protection of the electromotor against overheating</li>
<li>Switching off in limit positions from position and from thrust</li>
<li>Adjustable switching-off thrust from 50% to 100%</li>
<li>Thrust blocking in limit positions</li>
<li>Thrust blocking during the start</li>
<li>2 freely programmable relays R1, R2 (Not valid for Profibus and Modbus)</li>
<li>Relay READY (Not valid for Profibus and Modbus)</li>
<li>Control by unified signal 0/4 &#8211; 20 mA, 4 &#8211; 12 mA, 12 &#8211; 20 mA, or 0/2 &#8211; 10 V (Not valid for Profibus and Modbus)</li>
<li>Control by permanent voltage (+24 V DC) &#8211; OPEN, CLOSE</li>
<li>Impulse control (inching duty) (+24 V DC) &#8211; OPEN, STOP, CLOSE</li>
<li>Timing mode / regime of operation</li>
<li>Safety function ESD (failure reaction)</li>
<li>Electronic position transmitter 4 to 20 mA passive (not for DMS3 in 2P version) (Not valid for Profibus and Modbus)</li>
<li>Auxiliary voltage output 24 V AC, max. 40 mA for supply of the control inputs</li>
<li>Output of failure messages</li>
<li>Space heater operated by control unit</li>
<li>Communication interface RS 232</li>
<li>Programme for parameterization setting by PC</li>
<li>Mechanical connection &#8211; pillars</li>
<li>Manual control</li>
<li>Enclosure protection IP 66</li>
</ul>
<h3>Additional equipment</h3>
<ul>
<li>Supply voltage:
<ul>
<li>3&#215;400 V, 3&#215;380 V, 220 V / 50 Hz</li>
<li>120 V, 110 V / 60 Hz</li>
</ul>
</li>
<li>Local control for actuators with DMS 3 system</li>
<li>Reversing unit for 3-phase supply voltage</li>
<li>Additional relays RE3, RE4, RE5</li>
<li>Additional relay module RE1, RE2, RE3, RE4, RE5, READY</li>
<li>Version with control board PROFIBUS DP V0/V1</li>
<li>Version with control board MODBUS RTU</li>
<li>Communication cable DB-9F/RJ45</li>
<li>Terminal box with type of protection &#8220;e&#8221;</li>
<li>Cable glands for armoured cables</li>
<li>Mechanical connection &#8211; flange</li>
<li>Mechanical connection according to ISO 5210 &#8211; flange size F07</li>
<li>Mechanical connection according to ISO 5210 &#8211; flange size F10</li>
<li>Enclosure protection IP 68</li>
</ul>
<p>Príspevok <a href="https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-ulr-2-pa-ex/">Explosion-proof electric linear actuator ULR 2 PA-Ex</a> zobrazený najskôr <a href="https://marvelpit.sk/en/">MARVEL P.I.&amp;T. | MARVEL-BMT | Electric actuators</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://marvelpit.sk/en/product/explosion-proof-electric-linear-actuator-ulr-2-pa-ex/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
